Application:
widely used for industry reactor, Mixing tank and automatically dosing.
Features:
Duble channels PID adjustment.
Three point buffer solution calibration , support for 4.00, 6.86, 9.18 adjustment.
Isolated Meter/Transmitter Mode output which is compatible with all types of PLC
24V safety power supply.
Sealed case ensures the operation in wet and salinity fog enviorment
Suitable for various dosing pump drived by pulse signal.
Model: pH/ORP-7672
Measurement items: pH
Sensor: double/triple combination pH sensor
Power supply: DC 24V±6V
Measurement range: pH : 0.00~14.00pH
Temperature:0.0~99.9℃
Resolution: pH : 0.01pH
Temperature:0.1℃
Accuracy: pH :±0.1
Temperature:±1℃
Temperature compensation component: NTC 10K
Working enviroment: 0~50℃
Transmit output: Isolated 4~20mA output the maximum load impedance ≤500Ω
PID control output:
idouble channels isolated configuration setting OC output
load capacity AC 220V 2A(MAX)/DC 24V 2A(MAX)
Installation: Panel mounted,fast installation clamp
Dimension: 96mm×96mm×105mm(H×W×D)
Slot dimension: 91mm×91mm(H×W)
|
??????? ???????? ?????? ?????
????? ?????? 03-6764586